Heatit Z-TRM2fx

Heatit Z-TRM2fx is an electronic thermostat for electrical floor heating. The thermostat has a built-in Z-Wave chip that can be connected with Home Automation systems like Fibaro, Futurehome, Smarthings, Homeseer, Vera, Zipato etc.

Heatit Z-TRM2fx is equipped with a single pole switch and it fits most System 55 frames (Elko RS16, Schneider Exxact, Gira, Jung etc.). The thermostat can withstand a load of max 13A /2900W at 230V. At higher loads the thermostat must control a contactor. The thermostat may be connected to two wired external sensors.

The thermostat has the capacity of up to 5 associations (relays, wall plugs etc.).

The thermostat is designed for electrical heating. It can also be used for waterborne floor heating when linked with Heatit Z-Water.

Article number: 54 304 60


   

CUSTOM COLOR COMBINATIONS

Due to the fact that many of our thermostats are available in both white and black, you may combine frames and fronts as you please. Choose a black frame with a white front (or the other way around) for an edgy look, or go for the traditional all-white or all-black.

Heatit_z_wave_white-white

Heatit Z-therm2 White RAL 9003

Color and design matching the Schneider Exxact series.

Heatit_z_wave_White-Front-Black
Heatit_z_wave_black-front-white
Heatit_z_wave_Black-Black

Heatit Z-Therm2 RAL 9011

Design matching the Schneider Exxact series.

FEATURES

  • Floor sensor
  • External room sensor
  • Temperature limiter
  • Weekly program/setback via gateway or pilot wire
  • Multilevel sensor command class
  • Firmware updates (OTA)
  • Power metering
  • LED-diode
  • Can be used in connection with different NTC-sensors
  • Lock mode/child lock
  • Calibration
  • 5 associations
  • Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class

This is a Z-Wave plus product with S2 security. In order to use S2 security, your gateway must support S2-inclusion.

Technical data

Protocol Z-Wave 868,4 MHz
SDK 6.71.03
Chip Z-Wave 500 chip
Rated voltage 230V 50/60Hz
Max load 2900W (resistive load)
750W self-limiting heating cable
Max current 13A
Power consumption <2,0W
Min/max installation temp -20°C – 40°C
Min/max operating temp 5°C – 40°C
Temperature intervals Floor sensor 5°C – 40°C. External room sensor 5°C – 40°C
Hysteresis 0,3°C – 3,0°C (default 0,5°C)
Switch Single-pole switch
Included in package Floor sensor, Art. no. 54 301 07
Compatible with NTC sensors with values 10, 12, 15, 22, 33 and 47 kΩ @ 25°C
IP Class IP 21
Approvals Z-Wave Plus, CE, EN 60730-1, EN 60730-2-9, EMC 2014/30/EU, RoHS 2011/65/EU, LVD 2014/35/EU
Terminal Use 1,5mm² or 2,5mm² according to load.

WARRANTY

2 years

Dimensions

measurements-heatit-z-trm2fx

Download documents

Sensors

Art. no. Product
54 30 560 Floor sensor  Ø3mm  6 meters  NTC 10 kΩ
54 30 546 Plastic frame for Heatit (front and frame) Black RAL 9011
54 301 07 Floor sensor  Ø4mm  3 meters  NTC 10 kΩ
54 301 28 External room sensor  NTC 10 kΩ
54 304 71 External enclosed sensor  IP 20/54

The product must be installed in accordance with the current version of the installation guide and national building codes. See the installation guide for further information.